31 Jul 2010
Support Center
»
Knowledgebase
»
SightMax 7 Live Chat - Cannot add duplicate collection entry of type 'add' with unique key attribute 'name' set to 'ScriptModule'
SightMax 7 Live Chat - Cannot add duplicate collection entry of type 'add' with unique key attribute 'name' set to 'ScriptModule'
Solution
When browsing the SightMax Service file you receive an error:
Cannot add duplicate collection entry of type 'add' with unique key attribute 'name' set to 'ScriptModule'
<add name="ScriptModule" preCondition="integratedMode" type="System.Web.Handlers.ScriptModule, System.Web.Extensions, Version=3.5.0.0, Culture=neutral, PublicKeyToken=31BF3856AD364E35"/>
Solution:
Edit your web.config in the WebService and add the following line in the right section (either httpmodules, or httphandlers, depending on what the error is).
<remove name="ScriptModule" />
Save the web.config file and browse the SVC file again.